Half-life.

It might be longer than a patient’s remaining whole life. This haunting case report describes detectable workplace lutetium 177 an entire month after an ill-informed cremation of a patient who died days after his Lutathera injection. More terrifying was the one-month out detectable technetium 99m in the urine of the crematory operator. | Yu, JAMA 2019